- Description
- Attributes
- Documents
- 6000-Count display
- Easy operation for speedy measurement
- Display of multiple measurement parameters
- Different models for different applications
- DT4251: Replaced with DT4255
- DT4252: High-precision DC voltage and 10A AC/DC measurements; offering a range of measurement capabilities
- DT4253: Make temperature, DC current (mA/μA). Ideal for HVAC
- CATIV 600V design for maximum safety
- Three-year warranty
DT4251: Measure current with clamp sensors - no exposed current terminals ensure safety. Ideal for when measurement safety is the top priority.
- No ‘A' terminal
- Includes clamp sensor connection terminals* and voltage detector
DT4252: High precision 600mV DC range and wide array of measurement features for all applications. Great for those who require a range of measurement capabilities.
- High precision 600mV range
- 6A and 10A ranges
DT4253: Temperature, DC mA & μA ranges for instrumentation and HVAC. Ideal for users responsible for maintaining instrumentation, heating, ventilation, or air conditioning equipment.
- 60μA to 60mA range
- Includes temperature measurement
DT4254: voltage-only model that addresses the cause of short-circuits at the root by intentionally removing the current measurement terminals
- 600.0 mV to 1500 VDC
- 6.000 V to 1000 VAC
DT4255: Clamp-based current measurement to eliminate contact with energized parts
- 600.0 mV to 1000 VDC
- 10.00 A to 1000 A Clamp
DT4256: voltage, current, resistance, capacitance, frequency, continuity check, and diode test functionality
- 600.0 mV to 1000 VDC
- 10.00 A to 1000 A Clamp
DT4252 | DT4253 | DT4254 | DT4255 | DT4256 | |
---|---|---|---|---|---|
TRMS | Yes | Yes | Yes | Yes | Yes |
DCV basic accuracy | ±0.3 %rdg. ±5 dgt. | ±0.3 %rdg. ±3 dgt. | |||
DC voltage | 600mV to 1000V | 600mV to 1500V | 600mV to 1000V | ||
DCA current | 6A to 10A | 60μA to 60mA |
|
N/A | 60.00 mA to 10.00 A |
ACA current | 6A to 10A | N/A | N/A | N/A | 600.0 mA to 10.00 A |
AC clamp* | N/A | 10A to 1000A | N/A | 10.00 A to 1000 A | 10.00 A to 1000 A |
Resistance | 600Ω to 60MΩ | N/A | 600Ω to 60MΩ | ||
Temperature | N/A | -40°C to 400°C |
|
||
Capacitance | 1μF to 10mF | N/A | 1μF to 10mF | ||
Frequency | 99Hz to 99kHz |
Includes: L9207-10 Test lead, Instruction Manual, four (4) LR03 Alkaline batteries, and Holster (attached to the instrument, with a test lead holder.).