{"product_id":"rohde-schwarz-rtb24-100-oscilloscope-rtb24-100","title":"Rohde \u0026 Schwarz RTB24-100 Oscilloscope, 4 CH, 100MHz, 2.5GS\/s, 20Mpts, 10-Bit, RTB 2 Series","description":"\u003cdiv class=\"custom-container\"\u003e\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003ch3\u003eRohde \u0026amp; Schwarz RTB 2 Series - RTB24-100 Oscilloscope\u003c\/h3\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003e\u003cstrong\u003eKey Facts:\u003c\/strong\u003e\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003eAnalog channels: 4\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDigital channels: Up to 16 with R\u0026amp;S RTB2-B1 mixed signal option\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eBandwidth: 100 MHz\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eSample rate: up to 2.5 Gsample\/s\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eMemory depth: up to 20 Msample\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eADC resolution: 10 bit\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eDisplay: 10.1\" capacitive touchscreen\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_12_0325_W_500px.jpg\" alt=\"The Perfect Choice\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\u003cdiv\u003e\u003cdiv class=\"tableWrapper\"\u003e\u003ctable style=\"min-width: 50px;\"\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eYour Benefits\u003c\/p\u003e\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eFeatures\u003c\/p\u003e\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eSee small signal details in the presence of large signals\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003e10-bit ADC, 1280 × 800 pixel display resolution\u003c\/p\u003e\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\u003cp\u003eCapture more time at full bandwidth\u003c\/p\u003e\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp\u003e2.5 Gsample\/s max. sample rate with up to 20 Msample memory,\u003c\/p\u003e\n\u003cp\u003e12 horizontal grid lines\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp\u003eEasier to see and collaborate.\u003c\/p\u003e\n\u003cp\u003eFaster to operate and interpret results.\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp\u003e10.1\" capacitive touchscreen with 1280 × 800 resolution,\u003c\/p\u003e\n\u003cp\u003egrid annotation, split dual window\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003ePower of ten for every task, everyday\u003c\/h3\u003e\n\u003cp\u003eR\u0026amp;S RTB 2 series oscilloscopes combine the power of ten with smart operating concepts to make them a perfect general-purpose tool for students, hobbyists, technicians and engineers. The R\u0026amp;S RTB 2 series is the follow up to the high-performance R\u0026amp;S RTB2000 oscilloscope. Try one in the lab and see the difference.\u003c\/p\u003e\n\u003cp\u003e\u003cstrong\u003ePower of ten:\u003c\/strong\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003e10-bit ADC\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e10 Mpoints memory\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e10.1\" capacitive touchscreen\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e10 s boot time\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003e10-in-1 instruments\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_01_0325_W_500px-13.jpg\" alt=\"R\u0026amp;S Essential\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eSignal analysis: quick results\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eSee small signal details in the presence of large signals\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe R\u0026amp;S RTB 2 features a customized Rohde \u0026amp; Schwarz engineered 10-bit A\/D converter that delivers a fourfold improvement compared to conventional 8-bit A\/D converters. The increased resolution results in sharper waveforms with more signal details that would otherwise be missed. One example is the characterization of switched-mode power supplies. The voltage across the switching device must be determined during the on\/off times within the same acquisition.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_13_0325_W_500px.jpg\" alt=\"10 bit vs 8 bit\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eCapture more time at full bandwidth\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e10 Msample standard and 20 Msample interleaved\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe R\u0026amp;S RTB 2 offers a class-leading memory depth: 10 Msample per channel are available, even 20 Msample in interleaved mode. This is 10 times more than similar oscilloscopes in the same instrument class. The user captures longer acquisition sequences even at high sampling rates, e.g. when analyzing transients of switched-mode power supplies, and thus benefits from more detailed analysis results.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_03_0325_W_500px.jpg\" alt=\"Capture more time at full bandwidth\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eSegmented memory\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e160 Msample with history function\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery R\u0026amp;S RTB 2 is equipped with a standard segmented memory functionality. Protocol-based signals with communications gaps such as I2C or SPI can be captured over several seconds or minutes. The variable segment size optimally utilizes the 160 Msample memory. In history mode, previous acquisitions in the maximum segmented memory depth of 160 Msample are available for further analysis.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_04_0325_W_500px.jpg\" alt=\"Segmented Memory\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eLogic analysis with the MSO option\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003e16 additional digital channels\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eEvery R\u0026amp;S RTB 2 is MSO ready, which allows the R\u0026amp;S RTB2-B1 option to enable up to 16 additional digital channels. The oscilloscope captures and analyzes signals from analog and digital components of an embedded design – synchronously and time-correlated to each other. For example, the delay between A\/D converter input and output can conveniently be determined with the cursor measurements.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_05_0325_W_500px.jpg\" alt=\"Logic Analysis\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eWaveform and pattern generator\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eGenerate analog and digital stimuli\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe R\u0026amp;S RTB-B6 waveform and pattern generator up to 50 Mbit\/s is useful for educational purposes and for implementing prototype hardware. Apart from the common sine, square\/pulse, ramp and noise waveforms, it outputs arbitrary waveforms and 4-bit signal patterns. Waveforms and patterns can be imported as CSV files or copied from oscilloscope waveforms. Predefined patterns including. I2C, SPI, UART and CAN\/LIN can be used.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_06_0325_W_500px.jpg\" alt=\"Waveform and pattern generator\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eDigital voltmeter\u003c\/h3\u003e\n\u003cp\u003e\u003cstrong\u003eMeasure and display electrical potential\u003c\/strong\u003e\u003c\/p\u003e\n\u003cp\u003eThe R\u0026amp;S RTB 2 features a 3-digit voltmeter (DVM) and 6-digit frequency counter on each channel for simultaneous measurements. Standard measurement functions include DC, AC+DC (RMS) and AC (RMS).\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_07_0325_W_500px.jpg\" alt=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_07_0325_W_500px.jpg\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eFrequency analysis mode\u003c\/h3\u003e\n\u003cp\u003eDifficult-to-find faults often result from the interaction between time and frequency signals. The FFT function of the R\u0026amp;S RTB 2 is activated at the push of a button and by simply entering the center frequency and span. Thanks to the R\u0026amp;S RTB 2 oscilloscopes’ high-performance FFT functionality, signals can be analyzed with up to 128 kpoints. Other practical tools include cursor measurements and autoset in frequency domain.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_08_0325_W_500px.jpg\" alt=\"Frequency Analysis Mode\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eMask test mode\u003c\/h3\u003e\n\u003cp\u003eMask tests quickly reveal whether a specific signal lies within defined tolerance limits. By using statistical pass\/fail evaluation, they assess quality and stability of a DUT. Signal anomalies and unexpected results are quickly identified. When the mask is violated, the measurement stops. Each violation can generate a pulse output at the AUX-OUT connector on the R\u0026amp;S RTB 2. This pulse output can be used to trigger actions in the measurement setup.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_09_0325_W_500px.jpg\" alt=\"Mask Test Mode\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eReady for the teaching lab\u003c\/h3\u003e\n\u003cp\u003eIn the teaching lab, the R\u0026amp;S RTB 2 oscilloscope is the perfect choice to teach students how to measure with an oscilloscope. It has an easy-to-use concept combined with state-of-the-art technology at an affordable price. The large 10.1\" high-resolution screen shows every signal detail, and one instrument can be shared among several students. Reports can be efficiently created with the handy, flexible screen annotation tool.\u003c\/p\u003e\n\u003c\/div\u003e\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\u003cimg src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/RS\/RTB-2-Series_10_0325_W_500px.jpg\" alt=\"Ready for Teaching\"\u003e\u003c\/div\u003e\u003c\/div\u003e\n\u003c\/div\u003e\u003cdiv class=\"custom-container\"\u003e\u003cdiv class=\"cr-teq-cc\"\u003e\u003cdiv\u003e\n\u003ch3\u003eIn The Box\u003c\/h3\u003e\n\u003cul\u003e\n\u003cli\u003e\u003cp\u003eRTB24-100 Oscilloscope\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eRT-ZP03 probes x 4\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003ePower cable\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eGetting Started Manual\u003c\/p\u003e\u003c\/li\u003e\n\u003cli\u003e\u003cp\u003eBasic Safety Instructions Brochure\u003c\/p\u003e\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\u003c\/div\u003e\u003c\/div\u003e","brand":"Rohde \u0026 Schwarz","offers":[{"title":"Default Title","offer_id":56669446963545,"sku":"20018131","price":3118.43,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/RTB24-Series_01_0325_75c1b3ca-800e-4fe0-9d0e-e973d0745b30.jpg?v=1764029753","url":"https:\/\/www.testequity.de\/en\/products\/rohde-schwarz-rtb24-100-oscilloscope-rtb24-100","provider":"TestEquity GmbH","version":"1.0","type":"link"}