{"product_id":"keysight-dp5782al-20020981","title":"Keysight DP5782AL DC Power Supply 20V, 375A, 7500W, In 3ph 170 - 265 VAC","description":"\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"TypographyStyle-sc-11lquxl vgLWy\"\u003eKeysight DP5782AL DC Power Supply Product Overview\u003c\/h3\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eThe Keysight DP5782AL is part of the DP5700 Series high-density DC power supplies, designed to deliver high power output in a compact 1U rack form factor. Its expert architecture delivers fast dynamic response, precise control, and efficient energy recovery. Built for space‑constrained lab and production settings, as well as demanding automated test environments (ATE), it delivers high performance, flexible system integration, and robust protection features.\u003c\/p\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eAs a 7.5 kW model, the DP5782AL provides stable and accurate voltage and current output with built-in measurement capabilities. It supports advanced system integration through standard interfaces, programmable control, and scalable configurations such as parallel and series connections. Additionally, security-focused features like a removable SD memory option make it suitable for sensitive or classified environments\u003c\/p\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\u003cspan class=\"LazyImageStyle-sc-1yh8pu8 dqpnc\" height=\"100%\" width=\"auto\"\u003e\u003cspan class=\"LazyImage-Placeholder\"\u003e\u003c\/span\u003e\u003cimg height=\"100%\" width=\"100%\" alt=\"DP5700 Series 7.5kW Models\" src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/Keysight\/DP5700A_7.5kW_And_PC_0526_500px_W.jpg\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"TypographyStyle-sc-11lquxl vgLWy\"\u003eSpecifications\u003c\/h3\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eSingle-phase 200 - 240 VAC input\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eOutput voltage range: 0 to 20 V\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eOutput current range: 0 to 375 A\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eMaximum output power: 7,500 W (7.5 kW)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eOutput ripple and noise: 10 mV (rms), 80 mV (peak-to-peak)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eLoad regulation: 7 mV (voltage), 300 mA (current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eLine regulation: 2 mV (voltage), 187.5 mA (current)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eVoltage programming accuracy: 10 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eCurrent programming accuracy: 0.1% + 750 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eVoltage measurement accuracy: 10 mV\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eCurrent measurement accuracy: 750 mA\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eTransient response: 1 ms recovery time\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eForm factor: 1U full rack height\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eInterfaces: LAN, USB, GPIB\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"TypographyStyle-sc-11lquxl vgLWy\"\u003eKey Benefits\u003c\/h3\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eHigh power density supply in a compact 1U design ideal for ATE racking\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eBuilt-in voltage and current measurements simplify monitoring and control\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eAdvanced protection features (OVP, OCP, OTP, UVP) safeguard connected devices\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eSystem scaling of twelve units in parallel (for current), two in series (for voltage)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eMultiple communication interfaces enable seamless system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eProgrammable internal resistance and arbitrary waveform generation support advanced testing scenarios\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eRemovable SD memory (option) improves data security for sensitive applications\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eAdjustable slew rate allows precise control of voltage transitions\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"TypographyStyle-sc-11lquxl vgLWy\"\u003eApplications\u003c\/h3\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eGeneral laboratory testing and validation in space-constrained environments\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eProduction and automated test system integration\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDevice and component performance characterization\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eSimulation of real-world power conditions using arbitrary waveform generation\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eTesting sensitive electronic devices requiring controlled voltage ramping\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eHigh-power applications requiring scalable voltage or current output\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eSecure testing environments requiring removable data storage\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eUsed in aerospace and defense, automotive, communications, and component manufacturing industries\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"tableWrapper\"\u003e\n\u003ctable\u003e\n\u003ccolgroup\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003ccol\u003e\n\u003c\/colgroup\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003e1.5 kW Models (1PH)\u003cbr\u003e1U Half-rack\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003e3.4 kW Models (1PH\/3PH)\u003cbr\u003e1U Full-rack\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003e5 kW Models (3PH)\u003cbr\u003e1U Full-rack\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003cth colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003e7.5 kW Models (3PH)\u003cbr\u003e1U Full-rack\u003c\/strong\u003e\u003c\/p\u003e\n\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e92 Total, Single-Output\u003cbr\u003eProgrammable Models\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDP5721A - DP5736A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDP5741A S\/L\/H -\u003cbr\u003eDP5756A S\/L\/H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDP5761A L\/H -\u003cbr\u003eDP5776A L\/H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDP5782A L\/H -\u003cbr\u003eDP5799A L\/H\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eVoltage\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 - 600V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 - 600V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 - 600V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 -1,500V\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eCurrent\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 - 150A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 - 340A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 - 500A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e0 - 375A\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003ePower\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e1.5 - 1.56 kW\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e3,360 - 3,450 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e5,000 - 5,200 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003ctd colspan=\"1\" rowspan=\"1\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e7,500 - 7,520 W\u003c\/p\u003e\n\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"TypographyStyle-sc-11lquxl vgLWy\"\u003eWhat's Included\u003c\/h3\u003e\n\u003cul class=\"UnorderedListStyle-sc-1koui9a koGePn\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eDP5782AL DC power supply\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eShips with the Keysight I\/O Library Suite\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e3 years of KeysightCare provides priority support\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003eNo line cords or terminations included (must be user supplied based on regional requirements)\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ul\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\u003cspan class=\"LazyImageStyle-sc-1yh8pu8 dqpnc\" height=\"100%\" width=\"auto\"\u003e\u003cspan class=\"LazyImage-Placeholder\"\u003e\u003c\/span\u003e\u003cimg height=\"100%\" width=\"100%\" alt=\"Keysight IO Libraries Suite and KeysighCare Support\" src=\"https:\/\/assets.testequity.com\/te1\/Images\/Web%20Images\/Keysight\/Keysight_IO_Library_KeyCare_0526_500px_W.jpg\"\u003e\u003c\/span\u003e\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003cdiv class=\"custom-container\"\u003e\n\u003cdiv class=\"cr-teq-cc\"\u003e\n\u003cdiv\u003e\n\u003ch3 class=\"TypographyStyle-sc-11lquxl vgLWy\"\u003eQuestions and Answers (FAQ)\u003c\/h3\u003e\n\u003col class=\"OrderedListStyle-sc-1tiw4p6 haaQjo\"\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003eWhat power capability does the DP5782AL provide?\u003c\/strong\u003e\u003cbr\u003eThe DP5782AL delivers up to 7.5 kW of output power with a voltage range of 0 to 20 V and current up to 375 A, making it suitable for high-power applications.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003eCan the DP5782AL be used in scalable systems?\u003c\/strong\u003e\u003cbr\u003eYes, multiple units can be connected in parallel to increase current or in series to increase voltage, enabling flexible system scaling for higher power requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003eDoes the unit include power cords or connectors?\u003c\/strong\u003e\u003cbr\u003eNo, line cords and terminations are not included with the unit. Users must supply appropriate cables based on local regulations and installation requirements.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003cli class=\"ListItemStyle-sc-1yqofwy gqiGZs\"\u003e\n\u003cp class=\"TypographyStyle-sc-11lquxl gYoVTJ\"\u003e\u003cstrong\u003eWhat does the NS1-class designation for Keysight instruments mean?\u003c\/strong\u003e\u003cbr\u003eThe NS1‑class designation identifies a tier of DC power supplies built for automated test environments (ATE). Keysight’s lineup breaks down into three tiers: Basic for economical, general‑purpose needs; Advanced (NS1‑class) for higher power, wider ranges, and enhanced programmability; and Pro\/Expert (NS1‑class \u0026amp; NS4‑class) for the most complex, dynamic‑load testing requiring maximum speed, accuracy, and efficiency.\u003c\/p\u003e\n\u003c\/li\u003e\n\u003c\/ol\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e\n\u003c\/div\u003e","brand":"Keysight","offers":[{"title":"Default Title","offer_id":58782944330073,"sku":"20020981","price":14713.0,"currency_code":"EUR","in_stock":false}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/20020981.jpg?v=1786033786","url":"https:\/\/www.testequity.de\/en\/products\/keysight-dp5782al-20020981","provider":"TestEquity GmbH","version":"1.0","type":"link"}