{"title":"GW Instek Electronic Loads","description":"\u003cp\u003e\u003cspan\u003eGW Instek's PEL-3000 Series provides high-performance single-channel programmable DC electronic loads, like the PEL-303xE, crucial for maintaining quality and performance in labs and production, driving innovation as technology evolves.\u003c\/span\u003e\u003c\/p\u003e","products":[{"product_id":"gw-instek-pel-2004a-programmable-dc-electronic-load-mainframe-pel-2004a","title":"GW Instek PEL-2004A Programmable DC Electronic Load Mainframe, 4-Slot, 4x350W, PEL-2000A Series","description":"\u003cp\u003eThe PEL-2004A and PEL-2002A are multiple channel, programmable DC electronic loads with a modularized structure. The PEL-2000A Series is designed to meet the continuing shift toward high speed operation in today's semiconductor market. As the power supply units, DC-DC converters, and batteries that drive semiconductor circuits to follow this shift, power supply design, quality inspection, and characteristic certification using high-speed performance loads have become necessary.\u003c\/p\u003e\n\n \n\u003cp\u003eFor higher load capacities, mainframes can be linked together in parallel with standard MIL 20-pin connectors. A maximum of 5 mainframes, including one master and 4 slaves can be chained together to create a total load capacity of 7kW for high current and high power applications. Using 4 dual channel load modules, the PEL-2004A is able to test 8 power supply outputs simultaneously.\u003c\/p\u003e\n\n\u003cp\u003eThe Sequence function allows each channel to change its load sink according to a predefined sequence at a rate of up to 100 s per step. Each sequence is able to run concurrently under the control of one clock. This is one of the most powerful features of the PEL-2000A ASeries as it is able to realistically simulate a multi-output power supply load. Under Dynamic mode, the load current or load resistance pulses between two preset levels at a pre-defined speed up to 25 s per step. This is often used as the standard test procedure to verify the response of a power supply to quick load changes. Most remarkably, multiple load channels can be connected in parallel to run Dynamic tests synchronously under a single clock. This Parallel Dynamic functionality gives the flexibility to perform dynamic tests for a high-power power supply without the need of another high-power load.\u003c\/p\u003e\n\n\u003cp\u003eThe Go\/NoGo function is available to monitor test results all the time. When a test result goes beyond a preset limit range, a \"No Go\" indication will be shown on the display and a \"No Go\" signal can be sent out through the D-SUB interface for external device control. This Go\/NoGo function is available for CC mode, CV mode, and CR mode. Under \"Program\" mode, 12 programs, each containing 10 panel setup memories, can be edited to create work routines for repetitive tests. After a program has been executed, the results of all test steps, along with the Go\/NoGo judgments, will be shown on the screen.\u003c\/p\u003e\n\n\u003cp\u003eFor external control and system configuration, the PEL-2000A series has USB and RS-232 interfaces as standard and GPIB as an option. The LabView driver and Data Logging PC software are both supported for all the available interfaces. Each channel has an analog control\/monitoring connector on the rear panel to externally turn a load on\/off and to externally monitor load input current and voltage.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003e4-Slot Programmable D.C. Electronic Load Mainframe\u003c\/li\u003e\n\u003cli\u003eSequence function to do high Efficient load simulations\u003c\/li\u003e\n\u003cli\u003eFlexible configuration with mainframes and plug-in modules\u003c\/li\u003e\n\u003cli\u003eMultiple independent load inputs up to 8 channels in a mainframe\u003c\/li\u003e\n\u003cli\u003eParallel connection of inputs for increased load capacity\u003c\/li\u003e\n\u003cli\u003eParallel connection of inputs for static and dynamic tests\u003c\/li\u003e\n\u003cli\u003eOPP\/OCP\/OVP\/OTP protections\u003c\/li\u003e\n\u003cli\u003eExternal channel control\/monitoring via an analog control connector\u003c\/li\u003e\n\u003cli\u003eMulti-Interface USB Device \/ Host, RS-232C, and GPIB (Optional)\u003c\/li\u003e\n\u003cli\u003e2 Year Warranty\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56669473177945,"sku":"18947.2","price":1566.0,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/instek-pel-2004a-dc-load-4channel-mainframe-02_41c9e80b-4377-450a-bd5c-1a63a1486aec.jpg?v=1764027902"},{"product_id":"gw-instek-pel-2020b-dc-electronic-load-module-pel-2020b","title":"GW Instek PEL-2020B DC Electronic Load Module, Dual Channel, 80V, 20A, 100W, PEL-2000 Series","description":"\u003cul\u003e\n\u003cli\u003eMainframe required for operation \/ sold separately\n\u003c\/li\u003e\n\u003cli\u003eThis product is only a module\n\u003c\/li\u003e\n\u003cli\u003eDual channel DC load module\n\u003c\/li\u003e\n\u003cli\u003e0-80V, 0-20A, 100W (x2)\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cul\u003e\n  \u003cli\u003eMultiple independent load inputs up to 8 channels in a mainframe\u003c\/li\u003e\n  \u003cli\u003eSequence function to enable complex load simulations\u003c\/li\u003e\n  \u003cli\u003eFlexible configuration with mainframes and plug-in modules\u003c\/li\u003e\n  \u003cli\u003eParallel connection of inputs for increased load capacity\u003c\/li\u003e\n  \u003cli\u003eParallel connection of inputs for static and dynamic tests\u003c\/li\u003e\n  \u003cli\u003eMultiple channels run for dynamic tests under one clock control\u003c\/li\u003e\n  \u003cli\u003eMaximum rated power for low range high resolution CC tests\u003c\/li\u003e\n  \u003cli\u003eProgram mode to create work routines for repetitive tests\u003c\/li\u003e\n  \u003cli\u003eOPP\/OCP\/OVP\/OTP protections\u003c\/li\u003e\n  \u003cli\u003eExternal channel control\/monitoring via an analog control connector\u003c\/li\u003e\n  \u003cli\u003eUSB Device\/Host and RS-232C interface included\u003c\/li\u003e\n  \u003cli\u003eOptional GPIB\u003c\/li\u003e\n  \u003cli\u003eMulti-mainframe link up to 5 mainframes in a system\u003c\/li\u003e\n  \u003cli\u003ebackward-compatible with existing PEL-2000 products\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe PEL-2004 and PEL-2002 are multiple channel, programmable DC electronic loads with a modularized structure. \u003cbr\u003e\n  \u003cbr\u003e The PEL-2000 Series includes two types of mainframes and 4 types of load modules to accommodate users' requirements in a flexible manner. Any load module combination can be used with a mainframe to tailor a test system based on the number of channels, the maximum load power, voltage, and current of each channel. Multiple loads can be connected in parallel to provide a higher-power load. This flexibility significantly reduces the investment needed for future projects that have different power requirements. \u003cbr\u003e\n  \u003cbr\u003e The PEL-2004 is a 4-slot mainframe with a master control unit to hold 4 load modules, while PEL-2002 is a 2-slot mainframe with master control unit to hold 2 load modules. When the PEL-2004 is configured with 4 load modules rated at 350W each, the PEL-2002 is able to sink up to 1.4kW of power. \u003cbr\u003e\n  \u003cbr\u003e For higher load capacities, mainframes can be linked together in parallel with standard MIL 20-pin connectors. A maximum of 5 mainframes, including one master and 4 slaves can be chained together to create a total load capacity of 7kW for high current and high power applications. Using 4 dual channel load modules, the PEL-2004 is able to test 8 power supply outputs simultaneously. \u003cbr\u003e\n  \u003cbr\u003e The Sequence function allows each channel to change its load sink according to a predefined sequence at a rate of up to 100 s per step. Each sequence is able to run concurrently under the control of one clock. This is one of the most powerful features of the PEL-2000 Series as it is able to realistically simulate a multi-output power supply load. Under Dynamic mode, the load current or load resistance pulses between two preset levels at a pre-defined speed of up to 25 seconds per step. This is often used as the standard test procedure to verify the response of a power supply to quick load changes. Most remarkably, multiple load channels can be connected in parallel to run Dynamic tests synchronously under a single clock. This Parallel Dynamic functionality gives the flexibility to perform dynamic tests for a high-power power supply without the need of another high-power load.\n\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eIn The Box\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003eLoad module\u003c\/li\u003e\n\u003cli\u003eTest Lead GTL-120 x1\u003c\/li\u003e\n\u003cli\u003eSense Lead GTL-121 x1\u003c\/li\u003e\n\u003cli\u003eNote: mainframe sold separately and required for operation\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56669476454745,"sku":"45896.1","price":2112.01,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/PEL-2020B_0123_078c7bbe-f282-460b-9879-c4a0f2dc1fce.jpg?v=1764027904"},{"product_id":"gw-instek-pel-507-80-140-dc-electronic-load-accs-pel-507-80-140","title":"GW Instek PEL-507-80-140 DC Electronic Load Accs, 700W 80V\/140A Programmable DC Load","description":"\u003cp\u003e\u003cb\u003ePEL-500 Series DC Electronic Load\u003c\/b\u003e\u003c\/p\u003e\n\n\u003cp\u003e\u003cb\u003eFeatures\u003c\/b\u003e\u003c\/p\u003e\n\u003cul\u003e\n\u003cli\u003e5-digit digital voltage, current and power meter\u003c\/li\u003e\n\u003cli\u003eSimultaneous display of voltage, current, and watts\u003c\/li\u003e\n\u003cli\u003eShort-circuit time can be set during short-circuit test\u003c\/li\u003e\n\u003cli\u003eAutomatic test function of overcurrent protection\/overpower protection\u003c\/li\u003e\n\u003cli\u003eThe battery discharge test function can set the discharge stop voltage (Vbatt), discharge capacity (AH, WH) and stop discharge time.\u003c\/li\u003e\n\u003cli\u003eSurge test can simulate boot overshoot current and transient current from hot plugging.\u003c\/li\u003e\n\u003cli\u003eConstant current, constant resistance, constant voltage, constant power and Dynamic mode\u003c\/li\u003e\n\u003cli\u003eOvervoltage, overcurrent, over power, over temperature protection and reverse polarity detection\u003c\/li\u003e\n\u003cli\u003eVoltage polarity display can be set to positive value (\"+\") or negative value (\"-\")\u003c\/li\u003e\n\u003cli\u003eCommunications interface: RS232, USB\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe PEL-500 series single-channel electronic load has a total of 5 models and provides 0~80V\/ 0~500V voltage operating ranges and 250~700W power operating range. The series can be applied to R\u0026amp;D, quality control, ATE system and production test, including voltage source\/current source test; switching power supply transient response; constant voltage mode for current limiting test; battery simulation; and battery discharge test.\u003c\/p\u003e\n\n\u003cp\u003e\u003c\/p\u003e\u003ctable border=\"1\" cellpadding=\"5\" cellspacing=\"0\"\u003e\n\u003ctbody\u003e\n\u003ctr\u003e\n\u003cth colspan=\"4\"\u003ePEL-500 Series DC Electronic Load\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003cth\u003eModel\u003c\/th\u003e\n\u003cth\u003ePower\u003c\/th\u003e\n\u003cth\u003eVoltage\u003c\/th\u003e\n\u003cth\u003eCurrent\u003c\/th\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEL-503-80-50\u003c\/td\u003e\n\u003ctd\u003e250W\u003c\/td\u003e\n\u003ctd\u003e80V\u003c\/td\u003e\n\u003ctd\u003e50A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEL-504-80-70\u003c\/td\u003e\n\u003ctd\u003e350W\u003c\/td\u003e\n\u003ctd\u003e80V\u003c\/td\u003e\n\u003ctd\u003e70A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEL-504-500-15\u003c\/td\u003e\n\u003ctd\u003e350W\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003ctd\u003e15A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEL-507-80-140\u003c\/td\u003e\n\u003ctd\u003e700W\u003c\/td\u003e\n\u003ctd\u003e80V\u003c\/td\u003e\n\u003ctd\u003e140A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003ctr\u003e\n\u003ctd\u003ePEL-507-80-30\u003c\/td\u003e\n\u003ctd\u003e700W\u003c\/td\u003e\n\u003ctd\u003e500V\u003c\/td\u003e\n\u003ctd\u003e30A\u003c\/td\u003e\n\u003c\/tr\u003e\n\u003c\/tbody\u003e\n\u003c\/table\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56669476716889,"sku":"20005553","price":2500.96,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/PEL-507-80-140_01_0524_96d20230-3a5f-40e0-b782-f18f80d3b3d7.jpg?v=1764027909"},{"product_id":"gw-instek-pel-5006c-1200-240-dc-electronic-load-pel-5006c-1200-240","title":"GW Instek PEL-5006C-1200-240 DC Electronic Load, Single Input: 1200V, 240A, 6kW, PEL-5000C Series","description":"\u003cp\u003e\u003cb\u003eInstek PEL-5000C Series High Power Compact DC Load\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\n\u003cb\u003eFeatures\u003c\/b\u003e\n\u003c\/p\u003e\u003cul\u003e\n    \u003cli\u003eMaximum power up to 192KW\u003c\/li\u003e\n    \u003cli\u003eUp to 8 units of master\/slave parallel control\u003c\/li\u003e\n    \u003cli\u003e5-digit digital voltage, current and power meter\u003c\/li\u003e\n    \u003cli\u003eLarge LCD Display\u003c\/li\u003e\n    \u003cli\u003eDisplay voltage value, current value, watt value at the same time\u003c\/li\u003e\n    \u003cli\u003eSuitable for power factor regulator (PFC) testing (600V, 1200V models)\u003c\/li\u003e\n    \u003cli\u003eAutomatically perform OCP, OPP test\u003c\/li\u003e\n    \u003cli\u003eThe power-on state value can be set\u003c\/li\u003e\n    \u003cli\u003eConstant current, constant resistance, constant voltage, constant power, constant current + constant voltage, constant power + constant voltage, dynamic and short circuit modes\u003c\/li\u003e\n    \u003cli\u003eShort circuit time can be set during short circuit test\u003c\/li\u003e\n    \u003cli\u003eOver current, over power, over temperature protection and over voltage warning\u003c\/li\u003e\n    \u003cli\u003eVoltage polarity display can be set to positive or negative value\u003c\/li\u003e\n    \u003cli\u003eSupport solar panel MPPT test\u003c\/li\u003e\n    \u003cli\u003eOptional interface: GPIB, RS232, USB, LAN\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003e\u003cb\u003eGW Instek PEL-5000C series single-channel electronic load\u003c\/b\u003e provides 150V\/ 600V\/ 1200V models with a power range of 6kW~24kW. PEL-5000C has a total of 24 models featuring different combinations of power, voltage, and current. It can test and verify the specifications of batteries, electric vehicle chargers\/charging stations, electric vehicle batteries and solar panels. PEL-5000C supports parallel connection for same voltage specification and different power models. PEL-5000C can support up to 8 units connected in parallel to provide a maximum power of 192kW.\u003c\/p\u003e\n\u003cp\u003eFor the scenario of battery testing, \u003cb\u003ePEL-5000C specifically provides four battery discharge modes\u003c\/b\u003e, namely CC+CV battery discharge test mode, CP+CV battery discharge test mode, CC+ UVP battery discharge test mode, and CP+ UVP battery discharge test mode. Users can choose a suitable test mode according to the test requirements. In addition to the four battery discharge modes, \u003cb\u003ePEL-5000C also provides Time period discharge\u003c\/b\u003e, Pulse discharge, and RAMP discharge modes. Users can set the discharge time, or discharge in the pulse current mode, or even set the rising\/falling slew rate of the discharge current. These functions can be very flexible in the simulation of the battery discharge current waveform when an electric vehicle is running.\u003c\/p\u003e\n\u003cp\u003eIn order to meet the verification requirements of different DUTs, PEL-5000C provides a variety of test functions, including inrush current test mode, solar panel MPPT test mode, automated OCP, OPP test functions and 150 sets of parameter storage function. The 1200V model of PEL-5000C not only provides full power output at 1000V, but also provides 60% power output at 1200V output, which is higher than the 50% power output of other manufacturers of similar electronic loads. High-voltage batteries or chargers directly connected to the electronic load may cause damage to the electronic load. PEL-5000C has a built-in slow starter, which not only protects the DC load, but also saves the user's installation cost and setting time for measurement.\u003c\/p\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56669477142873,"sku":"32781.1","price":12154.48,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/instek-pel-5006c-1200-240-34306c-main-image.jpg?v=1764027907"},{"product_id":"gw-instek-ael-5006-425-56-acdc-single-input-electronic-load-ael-5006-425-56","title":"GW Instek AEL-5006-425-56 AC\/DC Single Input Electronic Load, 425V, 5,600W, AEL-5000 Series","description":"\u003cp\u003e\u003cb\u003eInstek AEL-5000 Series AC\/DC Load\u003c\/b\u003e\u003c\/p\u003e\n\u003cp\u003e\n\u003cb\u003eFeatures\u003c\/b\u003e\n\u003c\/p\u003e\u003cul\u003e\n    \u003cli\u003eCC, Linear CC, CR, CV, CP and AC Rectifier Load Mode\u003c\/li\u003e\n    \u003cli\u003eFrequency Range : DC, 40 to 440Hz\u003c\/li\u003e\n    \u003cli\u003eTurbo Mode for 2 Times the Current and Power of Electronic Load within 1 Second\u003c\/li\u003e\n    \u003cli\u003eThree Units Parallel up to 90kW and Three-phase Delta or Y Load Connection Can be Synchronized Control by One Master Unit\u003c\/li\u003e\n    \u003cli\u003eLoading and Unloading Angle Control; 0 to 359 Degree is Settable\u003c\/li\u003e\n    \u003cli\u003ePositive Half-cycle or Negative Half-cycle Loading\u003c\/li\u003e\n    \u003cli\u003eSupports SCR\/TRIAC Current Phase Modulation Waveforms,90 Degree Trailing Edge and Leading Edge\u003c\/li\u003e\n    \u003cli\u003eOptional Interface : GPIB, RS232, USB, LAN\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eGW Instek launches 20 models of the AEL-5000 series AC\/DC electronic loads depending on the power range. The power range of a single unit is from 1875W to 22500W, and up to \u003cb\u003e8 units can be connected in parallel\u003c\/b\u003e. The maximum power of single-phase parallel connection can reach 180kW, and the total power of 3-phase can reach 540kW, which are suitable for UPS, Inverter\/Breaker, AC Power Source, Battery, Fuse\/Breaker, DC Power Source and other applications.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe AEL-5000 series has built-in precision measurement circuits\u003c\/b\u003e such as 16-bit A\/D and DSP to provide accurate measurement items, which include voltage root mean square value (Vrms), current root mean square value (Arms), and watt value (Watt), volt-ampere (VA), crest factor (CF), power factor (PF), total harmonic distortion (THD), voltage total harmonic distortion (VTHD), current total harmonic distortion (ITHD) , peak current (Ipeak), maximum current (Amax), minimum current (Amin), maximum voltage (Vmax), minimum voltage (Vmin), time measurement. In addition, built-in test modes include UPS Efficiency, PV Inverter Efficiency, UPS Back-up time, Battery Discharge time, UPS transfer time, Fuse\/Breaker Trip\/Non-Trip, short circuit simulation, OCP, OPP and other test modes.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe AEL-5000 series has the Turbo mode\u003c\/b\u003e (ON or OFF can be selected) design, which can increase the current and power of the electronic load by 2 times in one second. For test applications that require transient high power and large current such as transient overload test of protective components or short circuit of Fuse\/Breaker and AC power supply, OCP and OPP tests etc.. The Turbo mode provides the most economical solution.\u003c\/p\u003e\n\u003cp\u003e\u003cb\u003eThe AEL-5000 series also supports the Load On startup\u003c\/b\u003e function (pre-set Load On). When the inverter or uninterruptible power supply is turned on, the series directly loads the set load current to verify that whether startup of the inverter or uninterrupted power supply connecting to the electrical appliance is stable. At the same time, the Load On start function can also set positive half cycle or negative half load to verify whether the output voltage of the inverter or uninterruptible power supply remains stable when the actual electrical appliance only has a positive half cycle or negative half cycle load current. Control load angle and unload angle can also be set (range 0~359 degrees) to verify the stability of the transient response of the inverter or uninterruptible power supply when the appliance is plugged in and unplugged. In addition, the series also supports SCR\/TRIAC current phase modulation waveform, 90 degree Trailing Edge and Leading Edge settings.\u003c\/p\u003e\n\u003cp\u003eFor the application of the adjustable bandwidth (BW) function, when the bandwidth of the DUT does not match the bandwidth of the AEL-5000 series, there will be oscillations. Users can reduce the BW setting value accordingly to meet the response speed of the DUT. Inrush Current verifies whether the transient response of the inverter output voltage is stable when the electrical appliance is turned on (Inrush Current) and when the electrical appliance is suddenly connected (Surge Current).\u003c\/p\u003e\n\u003cp\u003eThe entire series of AEL-5000 provides over-voltage warning, over-current, over-power, and over-temperature protection. Analog Input terminal can control constant current, constant power and other working modes through external voltage. Vmonitor\/Imonitor terminal is used to connect external voltage\/current monitoring device. In addition, a variety of optional control interfaces are provided such as GPIB, RS-232, USB, and LAN to meet the needs of system integration.\u003c\/p\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56669479174489,"sku":"32801.1","price":14808.56,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/instek-ael-5006-425-32711-main-image.jpg?v=1764027568"},{"product_id":"gw-instek-pel-2041a-dc-electronic-load-pel-2041a","title":"GW Instek PEL-2041A DC Electronic Load, Single Channel, 2.5 to 500V, 10A, 350W, PEL-2000A Series","description":"\u003cp\u003eThe PEL-2041A from GW Instek is PEL-2000A series single channel programmable DC electronic load with a modularized structure. It is designed to meet the continuing shift towards high speed operation. As the power supply units, DC to DC converters and batteries that drives semiconductor circuits need to follow this shift, power supply design, quality inspection and characteristics certification using high speed performance loads have become necessary.\u003c\/p\u003e\u003cul\u003e\n\u003cli\u003eVoltage current and power rating at high range is 2.5V to 500V, 0A to 10A, 350W\u003c\/li\u003e\n\u003cli\u003eSequence function to do high speed load simulations\u003c\/li\u003e\n\u003cli\u003eFlexible configuration with mainframes and plug-in modules\u003c\/li\u003e\n\u003cli\u003eMultiple independent load inputs up to 8 channel in a mainframe\u003c\/li\u003e\n\u003cli\u003eParallel connection of input for higher load capacity\u003c\/li\u003e\n\u003cli\u003eProgram mode to create work routines for repetitive tests\u003c\/li\u003e\n\u003cli\u003eOPP\/OCP\/OVP\/OTP\/RVP\/UVP protections\u003c\/li\u003e\n\u003cli\u003eLAbView driver and data logging PC software supports all interface\u003c\/li\u003e\n\u003cli\u003eExternal channel control\/ monitoring via analogue control connector\u003c\/li\u003e\n\u003cli\u003e12 different programs and 10 sequences to each program\u003c\/li\u003e\n\u003c\/ul\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56669487333721,"sku":"18948.3","price":2344.82,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/instek-pel-2041a-dc-electronic-load-module-front.jpg?v=1764027904"},{"product_id":"gw-instek-pel-2030a-dc-electronic-load-pel-2030a","title":"GW Instek PEL-2030A DC Electronic Load, Dual Channel, 80V\/5A\/30W, 80V\/40A\/250W, PEL-2000A Series","description":"\u003cul\u003e\n\u003cli\u003eMultiple independent load inputs up to 8 channels in a mainframe\u003c\/li\u003e\n\n\u003cli\u003eSequence function to enable complex load simulations\u003c\/li\u003e\n\n\u003cli\u003eFlexible configuration with mainframes and plug-in modules\u003c\/li\u003e\n\n\u003cli\u003eParallel connection of inputs for increased load capacity\u003c\/li\u003e\n\n\u003cli\u003eParallel connection of inputs for static and dynamic tests\u003c\/li\u003e\n\n\u003cli\u003eMultiple channels run for dynamic tests under one clock control\u003c\/li\u003e\n\n\u003cli\u003eMaximum rated power for low range high resolution CC tests\u003c\/li\u003e\n\n\u003cli\u003eProgram mode to create work routines for repetitive tests\u003c\/li\u003e\n\n\u003cli\u003eOPP\/OCP\/OVP\/OTP protections\u003c\/li\u003e\n\n\u003cli\u003eExternal channel control\/monitoring via an analog control connector\u003c\/li\u003e\n\n\u003cli\u003eUSB Device\/Host and RS-232C interface included\u003c\/li\u003e\n\n\u003cli\u003eOptional GPIB\u003c\/li\u003e\n\n\u003cli\u003eMulti-mainframe link up to 5 mainframes in a system\u003c\/li\u003e\n\n\u003cli\u003ebackward-compatible with existing PEL-2000 products\u003c\/li\u003e\n\u003c\/ul\u003e\u003cp\u003e\u003cimg hspace=\"2\" style=\"margin-left:20px;\" align=\"right\" src=\"https:\/\/assets.testequity.com\/te1\/Images\/new2\/instek\/taiwan-excellence-award.gif\" width=\"135\" height=\"73\" alt=\"Taiwan Excellence Award Winner!\"\u003e\u003c\/p\u003e\n\n\u003cp\u003eThe PEL-2004A and PEL-2002A are multiple channel, programmable DC electronic\n  loads with a modularized structure.\u003cbr\u003e\n  \u003cbr\u003e\nThe PEL-2000A Series includes two types of mainframes and 4 types of load modules\nto accommodate users' requirements in a flexible manner. Any load module combination\ncan be used with a mainframe to tailor a test system based on the number of channels,\nthe maximum load power, voltage, and current of each channel. Multiple loads\ncan be connected in parallel to provide a higher-power load. This flexibility\nsignificantly reduces the investment needed for future projects that have different\npower requirements. \u003cbr\u003e\n\u003cbr\u003e\nThe PEL-2004A is a 4-slot mainframe with a master control unit to hold 4 load\nmodules, while PEL-2002A is a 2-slot mainframe with master control unit to hold\n2 load modules. When the PEL-2004A is configured with 4 load modules rated at\n350W each, the PEL-2002A is able to sink up to 1.4kW of power.\u003cbr\u003e\n\u003cbr\u003e\nFor higher load capacities, mainframes can be linked together in parallel with\nstandard MIL 20-pin connectors. A maximum of 5 mainframes, including one master\nand 4 slaves can be chained together to create a total load capacity of 7kW for\nhigh current and high power applications. Using 4 dual channel load modules,\nthe PEL-2004A is able to test 8 power supply outputs simultaneously. \u003cbr\u003e\n\u003cbr\u003e\nThe Sequence function allows each channel to change its load sink according to\na predefined sequence at a rate of up to 100 s per step. Each sequence is able\nto run concurrently under the control of one clock. This is one of the most powerful\nfeatures of the PEL-2000A Series as it is able to realistically simulate a multi-output\npower supply load. Under Dynamic mode, the load current or load resistance pulses\nbetween two preset levels at a pre-defined speed of up to 25 seconds per step.\nThis is often used as the standard test procedure to verify the response of a\npower supply to quick load changes. Most remarkably, multiple load channels can\nbe connected in parallel to run Dynamic tests synchronously under a single clock.\nThis Parallel Dynamic functionality gives the flexibility to perform dynamic\ntests for a high-power power supply without the need of another high-power load.\u003c\/p\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56669487464793,"sku":"19213.4","price":2352.13,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/instek-pel-2030a-dc-electronic-load-module-front_e21a0188-654e-407a-b09a-2bbb0d8fc4c1.jpg?v=1764027905"},{"product_id":"gw-instek-pel-029-handles-pel-029","title":"GW Instek PEL-029 Handles, Rack accessories, For AEL-5002\/5003\/5004 DC Electronic Loads","description":"\u003cul\u003e\n\u003cli\u003eHandles\u003c\/li\u003e\n\u003cli\u003eRack Accessory\u003c\/li\u003e\n\u003cli\u003eFor AEL-5002\/5003\/5004\u003c\/li\u003e\n\u003c\/ul\u003e\n\n\u003cp\u003eThe Instek PEL-029 is a Handle for the racks of the AEL-5002\/5003\/5004\u003c\/p\u003e","brand":"GW Instek","offers":[{"title":"Default Title","offer_id":56670673633625,"sku":"58706.1","price":49.88,"currency_code":"EUR","in_stock":true}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/files\/PEL-029_01_1023.jpg?v=1764027899"}],"thumbnail_url":"\/\/cdn.shopify.com\/s\/files\/1\/0964\/5657\/3273\/collections\/gw_instek-spectrum-analyzer_dcf070ab-f877-4b87-baf7-85ef5846d6a1.jpg?v=1772813314","url":"https:\/\/www.testequity.de\/en\/collections\/gw-instek-electronic-loads.oembed","provider":"TestEquity GmbH","version":"1.0","type":"link"}